Assessment of the reliability of the Johns Hopkins/Agency for Healthcare Research and Quality hospital disaster drill evaluation tool.

Authors
Kaji AH ; Lewis RJ

STUDY OBJECTIVE: The Joint Commission requires hospitals to implement 2 disaster drills per year to test the response phase of their emergency management plans. Despite this requirement, there is no direct evidence that such drills improve disaster response. Furthermore, there is no generally accepted, validated tool to evaluate hospital performance during disaster drills. We characterize the internal and interrater reliability of a hospital disaster drill performance evaluation tool developed by the Johns Hopkins University Evidence-based Practice Center, under contract from the Agency for Healthcare Research and Quality (AHRQ). METHODS: We evaluated the reliability of the Johns Hopkins/AHRQ drill performance evaluation tool by applying it to multiple hospitals in Los Angeles County, CA, participating in the November 2005 California statewide disaster drill. Thirty-two fourth-year medical student observers were deployed to specific zones (incident command, triage, treatment, and decontamination) in participating hospitals. Each observer completed common tool items, as well as tool items specific to their hospital zone. Two hundred items from the tool were dichotomously coded as indicating better versus poorer preparedness. An unweighted 'raw performance' score was calculated by summing these dichotomous indicators. To quantify internal reliability, we calculated the Kuder-Richardson interitem consistency coefficient, and to assess interrater reliability, we computed the kappa coefficient for each of the 11 pairs of observers who were deployed within the same hospital and zone. RESULTS: Of 17 invited hospitals, 6 agreed to participate. The raw performance scores for the 94 common items ranged from 18 (19%) to 63 (67%) across hospitals and zones. The raw performance scores of zone-specific items ranged from 14 of 45 (31%) to 30 of 45 (67%) in the incident command zone, from 2 of 17 (12%) to 15 of 17 (88%) in the triage zone, from 19 of 26 (73%) to 22 of 26 (85%) in the treatment zone, and from 2 of 18 (11%) to 10 of 18 (56%) in the decontamination zone. The Kuder-Richardson internal reliability, by zone, ranged from 0.72 (95% confidence interval [CI] 0.58 to 0.87) in the treatment zone to 0.97 (95% CI 0.95 to 0.99) in the incident command zone. The interrater reliability ranged, across hospital zones, from 0.24 (95% CI 0.09 to 0.38) to 0.72 (95% CI 0.63 to 0.81) for the 11 pairs of observers. CONCLUSION: We found a high degree of internal reliability in the AHRQ instrument's items, suggesting the underlying construct of hospital preparedness is valid. Conversely, we found substantial variability in interrater reliability, suggesting that the instrument needs revision or substantial user training, as well as verification of interrater reliability in a particular setting before use.

Codebooks
SLR Criteria
Summary

 All data were entered into a Microsoft Access database. Statistical analysis was performed using SAS version 8.1 and Stata SE 8.

SLR Criteria
Summary

Quantitative disaster evaluation

Summary

Two hundred items from the tool were dichotomously coded as indicating better versus poorer

Summary

Thirty-two fourth-year medical student observers were deployed to specific zones (incident command, triage, treatment, and decontamination) in participating hospitals.Each observer completed common tool items, as well as tool items specific to their hospital zone

SLR Criteria
Summary

Data were obtained from the disaster drill evaluation form from each of the observers and recorded on a closed response data collection form.

SLR Criteria
Summary

The objective of our study was to assess the internal reliability and the interrater reliability of the AHRQ hospital drill performance evaluation tool by using a cohort of hospitals in Los Angeles County, participating in a statewide disaster drill in November 2005.

Summary

This study was limited by the small number of hospitals and the modest number of observer pairs. Because only 6 of 17 hospitals agreed to participate, there is a possibility the hospitals were not representative.

SLR Criteria
Summary

We found a high degree of internal reliability in the AHRQ instrument’s items, suggesting the underlying construct of hospital preparedness is valid.

SLR Criteria
Summary

Six of the 17 invited hospitals agreed to participate.

SLR Criteria
Summary

 The reliability of the Johns Hopkins/AHRQ drill performance evaluation tool was evaluated by applying it to multiple hospitals in Los Angeles County, CA, participating in the November 2005 California statewide disaster drill.

 

 

eu Il sito web Portfolio of Solutions è stato inizialmente sviluppato nell'ambito del progetto DRIVER+. Oggi, il servizio è gestito da AIT Austrian Institute of Technology GmbH, a beneficio della gestione europea delle . PoS è approvato e supportato dal Disaster Competence Network Austria (DCNA) così come dai progetti STAMINA e TeamAware H2020.